Access-Control Power: Controllers, Locks and Battery Backup
Electric locks are surge loads, access control needs battery backup, and failure locks people out. Covers load estimates, per-channel current, and 1U vs 2U.
Sizing a supply for access control is not the same as sizing one for cameras, and the camera calculation cannot simply be reused. Three differences matter, and each changes what the supply has to do.
1. Three differences from camera power
Electric locks are surge loads. The current drawn at the instant a lock releases is several times the steady-state value — for our models it can reach 2–3 A. The supply has to carry that transient, and a unit run continuously at its rating will trip protection at the moment of release.
Access control needs backup. Doors must still release when the fire system operates, so these projects normally carry a battery. Camera circuits generally do not.
A failure blocks people. One faulty supply can leave an entire building unable to open its doors, so overcurrent protection has to locate the fault to a single channel rather than trip the whole unit.
2. Estimating the load
The estimating figures given in our product data: an access controller about 5–10 W each, a card reader about 1–3 W each, an electric strike or magnetic lock about 3–6 W each (with a start-up surge 2–3 times the steady value), and exit buttons and doorbells negligible.
For a ten-door system: controllers 10 W, twenty readers at 2 W each = 40 W, ten locks at 5 W each = 50 W — about 100 W in the steady state, with a peak of roughly 150 W when several locks operate together. A 25 A / 300 W tier has ample margin for that load.
3. Per-channel current is the hard limit
Enough total power does not mean the devices can be connected. Access-control equipment is wired channel by channel, and the channel's current limit decides which devices can go on it.
Take PS-DC1216-10A-2U: DC12V, 8 channels (01–08), 1.25 A each. That suits readers and controllers, but a heavy-duty lock has to be checked against its actual figures. At the other end, PS-DC1225-1U has an adjustable output of 11–14 V, 25 A output current (300 W total) and 3 A per channel — that is the unit for high-current devices. List each device's nameplate current first, then compare with the channel limit; do not judge by total power alone.
4. Configuring battery backup
Our models accept an external 12 V battery for standby supply. Four points apply:
- Fit a diode in series with the battery positive, or use a dedicated charge-management circuit, to prevent reverse charging.
- Size the battery by the required standby time — from our data, a 12 V 7 Ah battery carries a 100 W load for about 40 minutes.
- Under long-term float charging, check battery condition periodically so a failed battery is not discovered during an outage.
- Whether a power failure releases or secures the doors depends on the lock type (fail-safe or fail-secure) and the system design, and must follow the fire code.
The last point matters most. Configure it the wrong way round and the doors stay locked during a fire, which is a far worse problem than the one the backup was meant to solve.
5. Wiring in the cabinet
Terminals on these models accept entry from front or rear, so new doors can be terminated on spare branches after the unit is racked without pulling the chassis out. On PS-DC1216-10A-2U the outputs are eight terminal groups, each with its own switch, fuse and status indicator.
Per-channel isolation is the point: a failed lock or reader takes out only its own channel and the other doors keep working. In a multi-door system that is a requirement, not an option.
6. What the voltage trim is for
DC outputs are ±10 % adjustable by default. Access-control circuits usually draw little current, but the distance from cabinet to lock can be considerable, and with an undersized cable the far-end voltage sags. Trimming the output upward brings it back into range. Calculate the actual drop from length, gauge and load current before deciding the setting.
Note that every channel on one chassis shares the same output voltage, so devices with different rated voltages cannot share a unit.
7. 1U or 2U
Where door points are concentrated, 1U saves rack space: PS-DC1225-1U is 44 mm high, 200 mm deep and 480 mm wide, with 3 A per channel, 25 A output current (300 W total) and a DC12V output adjustable between 11 and 14 V.
Where there are many locks and the current demand is higher, use 2U: PS-DC1216-10A-2U measures 433 × 360 × 89 mm (standard 2U), weighs 7 kg, and provides eight outputs at 1.25 A each.
Both will supply multi-door controllers together with several locks at once. The difference is the rack height consumed and the way current is divided across channels.
8. Frequently asked questions
How is the load estimated?
From our product data: controllers about 5–10 W each, readers about 1–3 W each, strikes and magnetic locks about 3–6 W each with a start-up surge 2–3 times the steady value; exit buttons and doorbells negligible. A ten-door system comes to roughly 100 W steady and 150 W peak, comfortably inside a 25 A / 300 W tier. Note that lock release current can reach 2–3 A, so the supply needs dynamic margin.
Is enough total power the only check?
No — check the per-channel current limit too. Access-control devices connect channel by channel, and that limit decides what fits where. PS-DC1216-10A-2U is DC12V with 8 channels at 1.25 A, suited to readers and controllers; a heavy-duty lock has to be checked against its actual figures. List nameplate currents and compare with the channel limit before choosing.
Can a battery be connected for standby power?
Yes — external 12 V batteries are supported. Fit a diode or charge-management circuit to prevent reverse charging; size the battery by standby time (12 V 7 Ah carries 100 W for about 40 minutes); check battery condition periodically under float charge; and confirm whether a failure should release or secure the doors, following the fire code — the wrong setting keeps doors locked during a fire.
Does one failed channel affect the other doors?
No. Each channel has its own switch, fuse and status indicator, so a failed lock or reader isolates to that channel and the other doors continue to work. In multi-door systems this is essential — tripping the whole unit would affect access to the entire building.
Need a model matched to your project?
Send the voltage class, device count and total load — we will confirm the model and the power headroom.