How Far Can a 12 V Centralized CCTV Supply Reach?
Distance is not fixed: ΔU = 2IρL/S sets it. A 10 W bullet on 1.0 mm² copper reaches about 41 m, or 33 m at 80 % margin. Method and wire-gauge table inside.
"How far can 12 V centralized power actually reach?" There is no single number of metres. The answer is set by three quantities: the camera current, the cable cross-section, and the voltage drop you are prepared to accept. This article works through the calculation for the most common arrangement — one camera per output channel — with the formula, the parameter values, a four-step method and a wire-gauge table.
1. Fix the arrangement first: one camera per circuit
Centralized power is wired in one of two ways.
Arrangement A (used here). Each output port feeds one cable, and that cable ends at a single camera. The current on each circuit is that camera's current, the circuits do not interact, and fault isolation is clean. This is how the great majority of rack-based installations are actually built.
Arrangement B. One trunk cable loops through several cameras (daisy chain). Current falls along the run, the drop has to be summed section by section, and the calculation gets complicated — the far end tends to fall short even on moderate runs.
Only Arrangement A is covered below; the daisy-chain case is handled in question 1 of the FAQ.
2. The cause: line voltage drop
Copper is not a perfect conductor — it has resistance. Current flowing through the cable produces a voltage drop:
ΔU = I × R
Cameras have a minimum input voltage. When a run is too long and the drop too large, the voltage at the camera port falls below that minimum and typical faults appear: the far camera will not start, or it reboots or goes black when the IR illuminator switches on, or the image flickers.
3. The core formulas
The resistance of a single conductor depends on material, cross-section and length:
R = ρ × L / S
A supply circuit is an out-and-back pair, so the total resistance doubles. Combining the two expressions gives the drop on one circuit:
ΔU = 2 × I × ρ × L / S (L = one-way length, S = cross-section of one conductor)
Rearranged, the maximum distance for a permitted drop is:
Lmax = ΔU × S / (2 × I × ρ)
Where ΔU is the permitted drop in volts, I the camera current in amps, ρ the resistivity of copper in Ω·mm²/m, S the cross-section in mm² and L the one-way length in metres.
Parameter values. Copper at 20 °C has a resistivity of about 0.0172–0.0185 Ω·mm²/m; engineering calculations commonly take ρ = 0.0175. Resistance rises slightly with temperature; these figures assume normal ambient.
4. Choosing the two inputs
Camera current. A typical IR bullet or dome is rated DC12V and its draw peaks with the illuminator on: roughly 3–5 W by day, 6–12 W at night. The working current is I = P / U, so 10 W ÷ 12 V ≈ 0.83 A. Three common estimates are used in practice: about 0.5 A (≈ 6 W), 0.8 A (≈ 10 W) and 1.0 A (≈ 12 W). Always confirm against the nameplate maximum.
Permitted drop. Most DC12V cameras accept 9–15 V input, a ±25 % window. For engineering purposes, however, keep the drop within 10 % of nominal:
ΔU recommended = 12 V × 10 % = 1.2 V (so the far end stays at 10.8 V or above)
A larger drop dims the IR output and leaves less margin against supply fluctuations. The table below uses 1.2 V; if the device datasheet confirms a wider window, it can be relaxed.
5. Four-step method
Example: one 10 W IR bullet on 1.0 mm² copper.
- Current. I = 10 W ÷ 12 V ≈ 0.83 A.
- Permitted drop. ΔU = 12 V × 10 % = 1.2 V.
- Maximum distance. Lmax = 1.2 × 1.0 / (2 × 0.83 × 0.0175) ≈ 41 m.
- Apply margin. Allowing for connector contact resistance, temperature and ageing, lay no more than 80 % of the theoretical figure: 41 m × 0.8 ≈ 33 m.
Second example: a 12 W camera (1.0 A) on 1.5 mm². Lmax = 1.2 × 1.5 / (2 × 1.0 × 0.0175) ≈ 51 m, so lay no more than about 41 m. Substitute your own figures into the same formula.
6. Wire gauge and current reference
| Cross-section (mm²) | 0.5 A camera (≈6 W) | 0.8 A camera (≈10 W) | 1.0 A camera (≈12 W) |
|---|---|---|---|
| 0.5 | ≈34 m | ≈21 m | ≈17 m |
| 0.75 | ≈51 m | ≈32 m | ≈26 m |
| 1.0 | ≈69 m | ≈43 m | ≈34 m |
| 1.5 | ≈103 m | ≈64 m | ≈51 m |
| 2.5 | ≈171 m | ≈107 m | ≈86 m |
These are theoretical one-way maxima at a 1.2 V drop. Lay to 80 % of them in practice. For points beyond about 80 m, consider the 24 V or PoE options in the next section.
7. When the distance is not enough
Use a heavier gauge — the simplest and most effective fix. Distance is proportional to cross-section: going from 1.0 mm² to 1.5 mm² multiplies the reach by 1.5, and to 2.5 mm² by 2.5.
Raise the output voltage. Most centralized supplies have a +V ADJ trimmer. Raising the input voltage raises the permitted absolute drop, so the reach scales roughly in proportion. Setting the output to 13.5 V, for example (most cameras accept up to 15 V), lifts the permitted drop from 1.2 V to 2.7 V and the theoretical reach by about 2.25×. Do not exceed the camera's input maximum — usually 15 V — or the device will be damaged, and check against maximum draw with the illuminator on.
Move to 24 V with a DC-DC converter at the camera. At the same power, 24 V halves the current; the absolute drop is half that of 12 V and the relative drop a quarter, so reach increases substantially. Suited to points beyond 80 m. See AC24V or DC12V for choosing between the two.
Use PoE for network cameras. PoE runs at 48 V, so the current is low, and standard cabling reaches 100 m with power and data on one cable. See Camera power options for the comparison.
8. Common misconceptions
How do I calculate a cable that loops through two cameras?
Section by section. On the first section (supply to camera 1) the current is that of both cameras; on the second (camera 1 to camera 2) it is only one. Total drop is the sum. Example: two 0.5 A cameras on 1.0 mm², first section 20 m and second 10 m — ΔU = 2 × 0.0175 × (20 × 1.0 + 10 × 0.5) / 1.0 ≈ 0.88 V. The earlier sections carry more current, which is why longer daisy chains fail at the far end.
Can I use the spare pairs in a network cable?
A standard Cat5e conductor is about 0.2 mm² (24 AWG); two in parallel give only about 0.4 mm², which the table above limits to 20–30 m. That is only suitable for very short runs. Use dedicated power cable or PoE for anything longer.
Why does the camera reboot or go black the moment the IR comes on?
IR LEDs draw roughly 30–50 % more than the daytime figure, so the current steps up and the drop with it. A distance calculated from the daytime figure will be short at night. Calculate from the nameplate maximum and keep a 20 % margin.
The supply has plenty of total power, so why does the far camera still fail?
Total supply capacity is not the same as adequate voltage at each far end. With one camera per circuit, reach is set by the drop on that circuit and is unrelated to the supply's total current rating (20 A, 30 A and so on). That is why the drop has to be checked separately after sizing the load and channel count.
In short: how far centralized power reaches is set by cable gauge and camera draw. On 1.0 mm² copper, a typical 10 W IR bullet reaches about 41 m in theory — keep it under 33 m. Going to 1.5 mm² extends that past 51 m. Read the nameplate, check the table, keep 20 % in reserve, and the "installed but black" call-back does not happen.
Data note: Ohm's law and published copper resistivity figures (about 0.0172–0.0185 Ω·mm²/m at 20 °C, taken here as 0.0175); camera draw and input windows follow mainstream nameplate values. Products referenced: PS-DC1208-1U (8 channels, 100 W) and PS-DC1229-16A-2U (16 channels, 350 W).
Need a model matched to your project?
Send the voltage class, device count and total load — we will confirm the model and the power headroom.